JensenTools
Information notification

Happy Thanksgiving! Our offices will be closed Thursday and Friday, November 28th & 29th.

Probe Master
Probe Master

Probe Master PT-8002 High Voltage Differential Probe, 25 MHz, 1:20/200, 1400V, PT-8000 Series

Our Part #10216131

Condition:New

Mfr Part #PT-8002

Probe Master PT-8002
Probe Master
Probe Master

Probe Master PT-8002 High Voltage Differential Probe, 25 MHz, 1:20/200, 1400V, PT-8000 Series

Our Part #10216131

Condition:New

Mfr Part #PT-8002

$390.00EACH
  • Bandwidth: DC-25MHz
  • Attenuation: X200, X20
  • Accuracy: +/-2%
  • Input voltage range
    Less than or equal to +/-140V for x20
    Less than or equal to +/-1400V for x200
  • Permitted max input voltage:
    Max differential voltage: 1400V(DC+AC PEAK)
    Max voltage between each input terminal and ground: 1KV RMS
  • Input Impedance:
    Each side: 4 Megaohms /2.5pF
    Between sides:8 Megaohms /1.3pF
  • Output voltage: Less than or equal to +/-7V
  • Output impedance: 50 Ohms
  • Rise time:
    14ns for x200
    14ns for x20
  • Rejection rate on common mode:
    50Hz:>-80dB; 20KHz:>-66dB
  • Power Supply: 6V DC power supply.
  • Consumption:0.3A max

The PT-8002 differential probe provides a safety means for measuring differential voltage to all models of oscilloscopes. It can convert the high differential voltage (less than or equal to +/- 1400V) into a low voltage(less than or equal to +/- 7V) and display on the oscilloscope. Its bandwidth is up to 25MHz, which is ideal for big power testing, development and maintain.
The PT-8002 is designed to operate with the 1 megaohm impedance oscilloscopes. When combined with the 50Ω ohms, the attenuation will be 2 times.

Brand: Probe Master
Bandwidth: 25 MHz
Attenuation: 200X, 20X
Input Capacitance: 1.3 pF
Max Input Voltage: 1400 V
Input Impedance: 8 MΩ
Series: PT-8000 Series
Operating Temperature Range: 0 to 50°C
Risetime: 14 ns
Safety Rating: CAT2 | CAT3
Type: Differential Probe
$390.00EACH